Laureate Series 4-20 mA Transmitters, Analog Process Input
Programmable DIN-rail 4-20
mA transmitters for DC voltage & current, AC RMS voltage & current,
process (e.g., 4-20 mA), strain, potentiometer follower, load cell, microvolt,
and temperature (thermocouple & RTD). Includes plug-in screw
clamp connectors and RS-232 / RS-485 port for programming.
To configure and price out
an instrument, select Quantity, press on the radio buttons below,
then on "Add items to shopping
cart." If you wish to construct a model number
so that your company can issue a purchase order, combine the radio
button selections to create a
model number in this format: TA202DCV1. This is for a 4-20 mA output
transmitter, standard main board, 95-240 Vac power, isolated dual
solid state relays, and a ±200.00 mV input signal.
Includes plug-in screw terminals.
|
| |
Laureate
4-20 mA Transmitter |
Quantity
|
|
Transmitter
Type |
TA Laureate 4-20 mA Transmitter. |
$235 |
Main Board |
2 Standard Main Board.
4 Extended Main Board |
NC
$40 |
| |
Note:
Extended allows custom curve linearization and rate from successive readings.
Not applicable to temperature. |
|
| Power |
0 Isolated 95-240
Vac & 95-300 Vdc
1
Isolated 10-34 Vac
& 10-48 Vdc. |
NC
$30 |
Setpoint
Output |
0 None.
2 Isolated Dual Solid State Relays. |
NC
$30 |
Signal
Input |
DC
Volts
DCV1
±200.00 mV.
DCV2
±2.0000 V.
DCV3
±20.000 V.
DCV4
±200.00 V.
DCV5
±300.0 V. |
NC |
DC
Amps
DCA1
±2.0000 mA.
DCA2
±20.000 mA.
DCA3
±200.00 mA.
DCA4
±5.000 A. |
NC |
Process
Signals (e.g., 4-20 mA, 0-5 V)
P Default
Scaling. 0-200 mV in = 4-20 mA out.
P1 Custom
Scaling.
In the write-in field of your invoice, specify min input, min reading; max input, max
reading. |
NC
$10 |
Strain
Gage, Potentiometer (4-wire ratio)
SG
Default
Scaling. 0-200 mV in = 4-20 mA out.
SG1
Custom
Scaling.
In the write-in field of your invoice, specify min input, min reading; max input, max
reading. |
NC
$10 |
True
AC RMS Volts
RMV1
200.00 mV.
RMV2
2.0000 V.
RMV3
20.000 V.
RMV4
200.00 V.
RMV5
600.0 V. |
$35 |
True
AC RMS Amps
RMA1
2.0000 mA.
RMA2
20.000 mA.
RMA3
200.00 mA.
RMA4
5.000 A. |
$35 |
| Note:
The same AC RMS signal conditioner can be user configured for AC Volts or AC Amps. It is
precalibrated in EEPROM for all AC Volt and AC Amp ranges listed. |
|
Thermocouples
JC Thermocouple Type J, -210°C to
760°C.
JF Thermocouple Type J, -347°F to
1400°F.
KC Thermocouple Type K, -347°C to
1372°C.
KF Thermocouple Type K, -408°F to
2501°F.
TC Thermocouple Type T, -257°C to
400°C.
TF Thermocouple Type T, -430°F to
752°F.
EC Thermocouple Type E, -240°C to
1000°C.
EF Thermocouple Type E, -400°F to
1830°F.
NC Thermocouple Type N, -240°C to
1000°C.
NF Thermocouple Type N, -410°F to
2370°F.
SC Thermocouple Type S, -46°C to
1768°C.
SF Thermocouple Type S, -51°F to
3214°F.
RC Thermocouple Type R, -45°C to
1768°C.
RF Thermocouple Type R, -49°F to
3213°F. |
NC |
RTDs
(100 Ohm Platinum)
P385C
RTD Alpha .00385, -202°C
to 850°C.
P385F
RTD Alpha .00385,
-331°F to 1562°F.
P392C
RTD Alpha .003925,
-202°C to 631°C.
P392F
RTD Alpha .003925,
-331°F to 1168°F. |
NC |
| Note:
The same temperature signal conditioner board can be user configured for all thermocouple
and RTD types listed. Temperatures for each type are spanned by a single range. |
|
Load
Cells (6-wire ratio)
WM Default Scaling. 0-20 mV in = 4-20 mA out.
WM1 Custom
Scaling.
In the write-in field of your invoice, specify min input, min reading; max input, max
reading. Full-scale input is 20-500 mV. 5V or 10V DC excitation for two
350-ohm load cells in parallel. |
$55 |
|
Accessories |
CBL03 RS-232 cable, TA to computer.
CBL02 USB to RS-232 cable adapter. |
Unselected.
Unselected. |
$19
$39 |