Laureate Series 4-20 mA Transmitters, Pulse or Process
Totalizer Input
Programmable DIN-rail
transmitters with 4-20 mA or 0-10V output. Available with dual pulse
inputs for frequency, rate, total, stopwatch, average time of period
events, phase, duty cycle, sum, difference, ratio or multiple of two
channels, and quadrature (position or rate). Also available with
signal conditioner to totalize analog process signals. Includes
plug-in screw clamp connectors and RS-232 / RS-485 port for
programming.
To configure and price out
an instrument, select Quantity, press on the radio buttons
below, then on "Add items to shopping cart." If you wish to
construct a model number so that your company can issue a purchase
order, combine the radio button selections to create a model number
in this format: TA202FR. This is for a 4-20 mA output
transmitter, standard main board, 95-240 Vac power, isolated dual
solid state relays, and dual channel frequency signal conditioner.
Includes detachable screw clamp connectors.
|
| |
Laureate
4-20 mA Transmitter |
Quantity
|
|
Transmitter
Type |
TA Laureate 4-20 mA Transmitter. |
$235 |
Main Board |
6 Standard Main Board.
8 Extended Main Board |
NC
$40 |
| Power |
0 Isolated 95-240
Vac & 95-300 Vdc
1
Isolated 10-34 Vac
& 10-48 Vdc. |
NC
$30 |
Setpoint
Output |
0 None.
2 Isolated Dual Solid State Relays. |
NC
$30 |
Input
Type |
Pulse
Rate or Totalizing
FR
Dual-Channel
Frequency.
- With Standard Main Board: Scalable to ±999,999 for
frequency, rate, square root of rate, up or down total, period, timing.
- With Extended Main Board: Above, plus rate and total
simultaneously, combinations of channels A&B (A+B, A-B, AxB, A/B-1),
phase angle, up/down counting, batch control, linearization of nonlinear
inputs.
|
NC |
Voltage-to-Frequency
Converter
VF1 V-to-F
Converter, 4-20 mA.
VF2 V-to-F
Converter, 0-1 mA.
VF3 V-to-F
Converter, 0-10 V.
In the write-in field of your invoice, specify min input, min reading; max input, max
reading. Component changes by the factory may be required.
- With Standard Main Board: Rate, square root of
rate, or total from differential pressure flow transducers with a DC output.
- With Extended Main Board: Above plus linearization of nonlinear inputs, batch
control, 1/rate (time).
|
NC |
Quadrature
QD
Quadrature.
- With Standard Main Board: Scalable to ±999,999 to
read out position, length or angle from shaft encoders.
- With Extended Main Board: Scalable to ±999,999 to
read out bi-directional rate or position from shaft encoders (not simultaneously).
|
$30 |
|
Accessories |
CBL03 RS-232 cable, TA to computer.
CBL02 USB to RS-232 cable adapter. |
Unselected.
Unselected. |
$19
$39 |