42213 Sarah Way, Temecula, CA 92590,
USA |
Tel: 800-854-8530 (USA)
Tel: 951-699-2437
Fax: 951-695-7246
sales@electronumerics.com |
 |
Micro Series Duty Cycle
Meter
For display of On or Off period
in percent
Features
- Available in three digit heights:
0.56" for panel mounting,
1.0" (Mighty-1) or
5.0" (Mighty-5) for
long-distance viewing.
- Measures ON or OFF period as a percentage
of total period.
- Resolution of 1%, 0.1% or 0.01%.
- Inputs from NPN or PNP proximity switches, contact
closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac.
- Trigger on positive or negative pulse
edges.
- Frequency from .005 Hz to 10 kHz.
- 6-digit red or green LED display.
- Isolated 5, 10 or 24 Vdc excitation
output to power sensors.
- Choice of isolated plug-in
options for control and computer interface:
dual
relays,
4-20 mA & 0-10
V analog output,
RS-232/485 serial I/O,
low voltage AC & DC power.
-
1/8 DIN
case environmentally sealed to NEMA-4X from front panel.
- 1/8 DIN
version certified to UL 3101-1, CAN/CSA-C22.2,
EN 61010-1 (CE Mark).
|

Description
Duty Cycle Mode
Duty cycle is a measure of ON or OFF period as a percentage of total period. Duty cycle is determined by averaging an integral number of periods over a gate time which is selectable from 10 ms to 199.99 s. The same signal is applied to Channels A and B. The meter divides
the average pulse width by the period between pulses and expresses this ratio in percent.
A resolution of 1%, 0.1% or 0.01% is selectable. By selecting leading or falling pulse
edges, the ON or OFF duty cycle can be displayed.
Duty cycle measurement is used to monitor
modulated proportional control systems and pulse-modulated systems, such as radar, lasers
or packet radio. For long periods, duty cycle can be measured by using the A and B
channels of the Micro dual-channel counter to totalize AC line cycles and having the
counter display the ratio of the two totals scaled to percent.
The Micro duty cycle meter
uses the FR dual-channel signal conditioner board and Extended counter
main board.
Universal Signal Conditioner
The dual-channel signal
conditioner accepts inputs from proximity switches with PNP or NPN output, TTL or CMOS
logic, magnetic pickups, contact closures, and AC signals from 12 mV to 250 Vac.
Jumper
selections provide optimum operation for different sensor types and noise
conditions.
A built-in isolated 5, 10, or 24 Vdc
excitation supply can power proximity switches and other sensors, and eliminate the need
for an external power supply.
Built-in Flexibility
Plug-in
isolated analog
output, dual setpoint controller,
and
RS-232/485
serial communications boards can
upgrade Micro and Mighty Series duty cycle meters from a stand-alone monitor to system interface and control. The
ability of the meter to output an isolated 0-10 V or 4-20 mA
analog signal turns into an analog transmitter.
Micro Series
meters can be powered from
95-240 Vac ±10% and 95-370 Vdc, or
optionally from 12-34 Vac and 10-48 Vdc.
Any setup functions and front panel keys may be locked out for
simplified usage and security. The popular
1/8
DIN version with 0.56" high digits is environmentally sealed to
NEMA-4X (IP65) from the front when panel mounted, and is
available with red or green LEDs.
|

Specifications
|
Phase
Angle Mode |
Item Displayed
Display Units
Frequency Range
Accuracy
Maximum Timing Interval |
Phase
angle difference between two waves of same period
1°, 0.1°, 0.01°
.005 Hz to 10 kHz
.01°, .005 Hz to 100 Hz, .1° at 1 kHz, 1° at 10 kHz
200 s |
|
Duty
Cycle Mode |
Item Displayed
Display Units
Frequency Range
Accuracy
Maximum Timing Interval |
ON
or OFF duty cycle of periodic pulse waveshape
1%, 0.1%, 0.01%
0.005 Hz to 50 kHz
0.01%, 0.005 Hz to 500 Hz, 0.1% at 5 kHz, 1% at 50 kHz
200 s |
|
Display |
Readout
Digit Height
Color
Range
Indicators |
6 digits, 7-segment
Available with 0.56", 1.0", 4.0" or 5.0" digits.
High brightness red. Green available with 0.56" digits.
-999999 to +999999
Four LED lamps |
|
Inputs |
Types
Signal ground
Selectable Hysteresis
Rolloff Filter
Debounce Time |
AC,
pulses from NPN, PNP transistors, contact closures, magnetic pickups
Common ground for channels A & B
-12 mV to +12 mV, +30 mV to +60 mV, -30 mV to -20 mV,
-150 mV to +150 mV, +350 mV to +600 mV, -600 mV to -350 mV,
-1.15 V to +1.15 V, +1.25 V to +2.1 V, -2.1 V to -1.25 V
Selectable: 1 MHz, 30 kHz, 250 Hz
Selectable: 0, 3, 50 ms |
|
Timing
Interval |
Periodic Timing
Interval
Gate Time
Timeout
Output & Display Update |
Gate
time + 30 ms + 0-2 signal periods
Selectable 10 ms to 199.99 s
Selectable 10 ms to 199.99 s
Same as period timing interval |
|
Power |
Voltage,
std.
Voltage, opt.
Frequency
Power isolation |
95-240 Vac ±10% and 95-370 Vdc
12-34 Vac and 10-48 Vdc
DC or 49-440 Hz
Safety-rated to 250 Vac, meter ground to earth ground,
DC to 60 Hz, 4.2 kVp per High Voltage Test |
|
Excitation Output |
5
Vdc
10 Vdc
24 Vdc
Output isolation |
5
Vdc ±5%, 100 mA max
10 Vdc ±5%, 120 mA max
24 Vdc ±5%, 50 mA max
50 Vdc to meter ground |
|
Environmental |
Operating Temperature
Storage Temp.
Relative Humidity
Protection |
0°C to 60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted |
|
Electrical Connections |
 |

|
Applications |
Duty Cycle Mode |
 |
Duty cycle indicates the ON or OFF time in percent from 0%
to 100% of period for repetitive pulse train. In the illustration, duty cycle is 100 x t /
P. The same signal is applied to the A and B channels.
|
Duty Cycle and Elapsed Time of a Laser |
 |
Duty cycle can be used to indicate the ON time of a pulsed
laser in relation to total time. Micro counters can also measure elapsed time, the
number of pulses, average width in µs, the number of pulses, and total energy applied.
|

Micro & Mighty Series Downloads
|